SanBlaze SSD Tester

The SANBlaze VirtuaLUN has been an excellent tool for traffic generation and performance testing at UNH-IOL plugfests for Fibre Channel and NVMe. We’re happy to use the VirtuaLUN as a resource in our lab for stressing systems when performing interoperability testing.”  — David Woolf, Engineering Manager – Datacenter, UNH-IOL

 

SANBlaze VirtuaLUN NVMe Initiator is the key piece of test equipment for anyone needing to test NVMe target devices. The VirtuaLUN feature set provides a unique set of functions applicable in all aspects of a product lifecycle; from development to design validation to test and QA. The ability to drive NVMe targets with a wide range of configurable attributes provides engineers with a flexible, scalable tool to simulate real disk and memory access environments and issues. Development, qualification and certification test cycles can be highly automated, reducing time and surfacing issues and errors.

 

The VirtuaLUN provides full control and programmability of NVMe parameters, providing unique storage test conditions for NVMe drive testing, development and certification. Additional support for updating and loading firmware, as well as support for secure erase, provide support for further automation steps and processes. Initiator emulation delivers the ability to drive multiple channels of traffic, inject errors, send specific or custom op codes in an easy to use, scriptable platform. Custom command generation and predefined tests provide simulated host environments. Auto connect and probe features quickly identify targets to test. Features such as Read/Write/Compare testing, error injection and a custom command builder provide an environment to drive and test single or multiple NVMe target devices.

 

Drive pulls can be automated via integration of the Quarch™ NVMe interposer card using REST API, scripting or Web based GUI. Performance testing during PCIe glitch insertion, data integrity during drive power margining and PCIe lane failure, controlled and surprise removal can all be automated via SANBlaze / Quarch integration.

 

Test cases can be saved and restored with a single command. Tests can be started via command line, scripted or via an easy to use Web based interface.

 

Key Features

 

  • Drive Firmware Download
  • Set Queue Count and Depth
  • NVMe Compare
  • Add/Remove/Modify Controller
  • Secure Erase
  • Read / Write and Compare Tests for traffic generation and data integrity
  • Dual Port/Multipath support
  • Error injection
  • Easy to use Web based interface
  • Command line interface and scripting
  • Save/load configurations
  • Trace Functionality
  • Error counters
  • T10 DIF support/error injection
  • Smart Monitoring
  • Compression and Dedup Data Pattern

Typical Applications 

  • NVMe Drive testing
  • Subsystem Performance testing
  • Dual Path device testing
  • Storage software verification
  • SAN management software verification
  • Performance testing
  • Error handling testing
  • Failover and Multipath Simulation
  • Scalability testing

Datasheet

Download
DT4 SANBlaze SBExpress-DT4 Data Sheet-10
Adobe Acrobat Document 3.4 MB
Download
SANBlaze SBExpress-RM GEN4 Data Sheet.pd
Adobe Acrobat Document 3.2 MB